Medical equipment and supplies
Home \ We offer \ Cardiac surgery \ Blood Gas and Electrolyte Analyzer OPTI CCA-TS2

Blood Gas and Electrolyte Analyzer OPTI CCA-TS2

OPTI CCA-TS2 Blood Gas and Electrolyte Analyzer
 
Provides fast accurate results for blood gases, acid-base balance, electrolytes, ionized calcium, glucose, BUN and lactate.
Runs samples of whole blood, plasma and serum on single-use disposable cassettes.
Uses innovative optical technology.
Requires minimal maintenance.
 
Innovative optical technology

The OPTI CCA-TS2 Blood Gas and Electrolyte Analyzer uses OPTI Medical’s optical fluorescence technology. This unique, patented technology does not use electrodes or contact points, which eliminates the need for costly electrode maintenance.
 
Significant cost savings

The OPTI CCA-TS2 analyzer provides lab-quality results with zero standby cost. The single-use consumable is only used during a measurement and safely locks waste inside.
 
Wide operating temperature

The OPTI CCA-TS2 analyzer has a measuring chamber heated to 37°C (98.6°F). This allows for a wide operating temperature range to meet the needs of colder environments, such as the operating room.
 
Comprehensive test menu

To help meet exact testing needs, the OPTI CCA-TS2 analyzer has a variety of cassette configurations available. Each cassette comes individually wrapped, in cartons of 25, reducing the potential for consumable waste.
 
Principles of operation

The OPTI CCA-TS2 Blood Gas and Electrolyte Analyzer is a microprocessor-based instrument that measures optical fluorescence from discreet sensors called optical electrodes (optodes). A disposable, single-use cassette contains all of the elements needed for calibration, sample measurement and waste containment. Specific calibration information from the cassette is read into the analyzer by swiping the cassette package through the bar-code reader. The cassette is then placed into the measurement chamber.
The analyzer warms the cassette to 37.0°C (±0.1°C)/98.6°F (±0.1°F), and it performs a calibration verification on the sensors for PCO2 and PO2 by passing a precision calibration gas mixture across the optode sensors. The pH and electrolyte channels are calibrated with precision buffer solution contained in the cassette. When calibration is verified, the analyzer aspirates the blood sample into the cassette and across the optode sensors. After equilibrating with the blood sample, fluorescence emission is then measured.
 
The OPTI CCA-TS2 single-use patient cassette includes these features:
  • Calibration of cassette before sampling—eliminates losing sample if cassette calibration fails
  • Long cassette shelf life—6–12 months from the date of manufacture
  • Easy and safe maintenance
  • Safe disposal—waste is locked in the cassette
  • Maintenance-free operation—no electrodes
  • Zero standby cost—no reagents required
 
OPTI CCA-TS2 analyzer specifications
 
Calibration/Measurement
Sample Volume 125 µL (60µL for B60 cassette)
Calibration Time <90 seconds
Measurement Time <120 seconds
Typical Cycle Time <210 seconds
Operating Temperature 10–30°C (50–86°F)
Sample Type Whole blood, serum or plasma
Measurement Principle Optical fluorescence, reflectance
Sample Application Syringe, capillary or ComfortSampler
Data Storage
500 patient records
70 QC samples per level
105 SRC samples per level
300 user IDs and passwords
 
Security

Password Multiple levels of security with user-definable permissions
QC Lockout User-definable QC lockout functions
 
Dimensions/Weight

Height x Width x Depth 124 x 362 x 230 mm (4.7 x 14.2 x 9.1 in)
Weight 4.3 kg (9.6 lb) with rechargeable battery pack
 
Miscellaneous

Voltage/Frequency 120 or 240 AC, 50–60 Hz
Power Consumption (max.) 110 VA
Interface ASTM, ASCII, POCT protocols via USB or Ethernet
Approvals CE, UL, IVDD, and FDA
 

Test menu

Ready-to-use single-use cassettes
The OPTI CCA-TS2 Blood Gas and Electrolyte Analyzer uses ready-to-use single-use cassettes that let you test for a range of blood gas parameters:
Cassette Tests
B-Type pH, PCO2, PO2, tHb, SO2
E-Type pH, PCO2, PO2, tHb, SO2, Na+, K+
E-Ca Type pH, PCO2, PO2, tHb, SO2, Na+, K+, Ca++
E-Cl Type pH, PCO2, PO2, tHb, SO2, Na+, K+, Cl-
E-GLU Type pH, PCO2, PO2, tHb, SO2, Na+, K+, GLU
E-BUN Type pH, PCO2, PO2, tHb, SO2, Na+, K+, BUN
B-LAC Type pH, PO2, tHb, SO2, LAC
B60 Type pH, PCO2, PO2
E-Lyte CCA Type pH, Na+, K+, Cl-, Ca++
 
The OPTI CCA-TS2 analyzer is easy to run:

The user-friendly touch screen, with simple menu navigation, can be used with minimal training.
Automated sample aspiration reduces staff time and training.
Heated measuring chamber allows for testing of iced samples.
 
How to use

Blood gas sampling in 4 easy steps
1. Scan the cassette bar code.
2. Remove the cassette from its packaging.
3. Place the cassette into the sample measurement chamber and close the cover.
4. Aspirate the sample. When sample aspiration and measurement is complete, the results will automatically appear on the screen.
Address:
Katta-Darkhan str., 25, Mirzo-Ulugbek dstr., Tashkent, Uzbekistan